WinNUT shuts down immediately when remaining battery time is "Unavailable", even if remaining time trigger set to 0 #195
Description
Activity
Hi there,
Sorry for taking awhile to get back to you. I want to say that it was intended for zero values to disable those checks, however I realize now that I may have introduced a slight bug here. WinNUT was designed originally such that when a variable was unavailable from the UPS, WinNUT would substitute the variable for a nominal value (so battery voltage would be set to 12V if it was unavailable, for example.) See #116. This probably worked fine in your scenario because the time remaining or percentage values would be nominal, thus effectively disabling those checks. However, I intentionally made it so that unavailable variables were set to out of range values, like 0 or -1. So I see now how this rendered the checks ineffective whenever a variable is missing.
I'm going to have to think how to approach this one a little bit (and your feedback is always appreciated.) On the one hand, I do want to fix the underlying system of how we handle variables in WinNUT - ideally, if a variable is unavailable, we'd just mark it as such. This could potentially indicate a need for me to accomplish an even greater project in #132 which is to transition the client code in WinNUT to a new library I've been working on. That could take quite a lot of work, however. On the other hand, I also want to overhaul how WinNUT handles events (see #92) and create a user-customizable system so people can create custom event handlers for different events.
I may have to think about this one for a little. In the meantime, does the Delay to Shutdown option let you at least delay the shutdown?
Thank You for the response! :)
I appreciate the long explaining! :)
Hope Your plans come true! :)
You asked about the workaround, and yes, the delay works, and holds back WinNUT from shutdown the PC as soon as the UPS lost power from the wall.
Have a great winter and coding! :)Zsolt
Reacted by gbakeman@gbakeman This is still having the same behaviour even after almost a year. But if it is so difficult finding a right approach, why not simply introduce a checkbox to ignore "time available?"
Hi @SebastianOehm,
Unfortunately a lot of other things have come up, and besides me getting sidetracked on a translation-related project for WinNUT I haven't been dedicating much time to other things that are affecting people so I have to apologize for that.
Looking back at this bug, I want to say that the simplest method for fixing it would be to modify this part of the code (note to future self) such that, if either of the two variables is set to -1 (indicating unavailable), WinNUT will not process that specific condition for powering down. Right now, my logic assumes that if one of the variables is unavailable, then both must be - which was obviously a faulty assumption.
I can't make any promises, but I do want to fix this bug at some point. Please stay tuned for more info!
- added a commit that references this issue
on Oct 19, 2025 Thanks for your PR @SebastianOehm ! I was getting a few things merged and ready to deploy, when I started running into a mysterious error in our old deployment system (something I've been working on for awhile to replace) so this pre-release could take awhile longer before it arrives.
Thanks again for your help troubleshooting this issue. A new Pre-Release build is out that I hope fixes this. I'll close this assuming all is well, but please comment back if issues persist.
Reacted by Sebastian Oehmtested, confirmed working! @gbakeman
Thanks again 😊
**WinNUT Version: **
v2.3.8988
**Windows OS Version: **
Win10 22H2
Describe the bug
My UPS (SPS-MID 1000 OnLine UPS) battery remaining time is unknown on the Synology DS420+ NAS, so the info transmitted to WinNUT Client also can not read the remaining time, so it is "Unavailable", and even if i set the "Shutdown if runtime lower than (sec)" is set to 0 (ZERO) the shutdown starts immediately.
ZERO value should disable the check for remaining battery runtime!
OR
There should be a logical operator to be able to set this one:
"Shutdown if battery lower than x%" OR "Shutdown if runtime lower than (sec)" will be the trigger (whichever comes true first)
or this one:
"Shutdown if battery lower than x%" AND "Shutdown if runtime lower than (sec)" will be the trigger if BOTH of them are true.
ZERO value disables the check for remaining battery percent, or battery remaining time.
To Reproduce
Steps to reproduce the behavior:
Expected behavior
I expect that WinNUT ignores the unavailable remaining time if i set the trigger to 0 sec. (and also the same for the remaining percent, if a UPS can not communicate this attribute to the SNMP server)
Screenshots
Additional context