Skip to content

Changed M105 response for EXTRUDERS > 1 - #70

Open
Idel (Idelmaeaen) wants to merge 4 commits into
Ultimaker:masterfrom
Idelmaeaen:Idel
Open

Idel (Idelmaeaen) wants to merge 4 commits into
Ultimaker:masterfrom
Idelmaeaen:Idel

Conversation

@Idelmaeaen

Copy link
Copy Markdown

Changed the resonse of M105 for printers with dual (or more)
extruders.
Now the actual and target temperature and also the output
power is
reoprted for each hotend.
Tested with:
-Simplify3D V2.2.2
(shows the temperature of both extruders at the
same
time)
-Repetier-Host V1.0.6 (Graph shows only the actual selected
hotend, the
status bar shows both hotends)

Changed the resonse of M105 for printers with dual (or more)
extruders.
Now the actual and target temperature and also the output
power is
reoprted for each hotend.
Tested with:
-Simplify3D V2.2.2
(shows the temperature of both extruders at the
same
time)
-Repetier-Host V1.0.6 (Graph shows only the actual selected
hotend, the
status bar shows both hotends)
@daid

daid commented May 6, 2015

Copy link
Copy Markdown
Contributor

Gina Häußge (@foosel) Your opinion on this?

@foosel

Copy link
Copy Markdown

This would result in things looking like this, right?

ok T:<tooltemp> /<tooltarget> B:<bedtemp> /<bedtarget> B@:<bedpower> @:<toolpower> T0:<tool0temp> /<tool0target> @0:<tool0power> T1:...

If so, that should be fine. Just from a purely visual point of view I find it a bit unintuitive that the power data for the currently selected tool follows after the bed segment though, that appears to be a bit out of order, but then it's always been like this in that the bed stuff "interrupts" the current tool information.

@daid

daid commented May 6, 2015

Copy link
Copy Markdown
Contributor

I'm not a huge fan of the tool power outputs, as they are pretty much useless anyhow. (If you enable PID_DEBUG you see the output has much more spread then you could ever see with M105)

@Idelmaeaen

Copy link
Copy Markdown
Author

Gina Häußge (@foosel): Yes it looks as you wrote...
You are right that the arrangement of the data is not really logical. I took the arrangement from the Repetier Firmware. See here:
https://github.com/repetier/Repetier-Firmware/blob/master/src/ArduinoDUE/Repetier/Commands.cpp#L147-L188

@ckielstra

Copy link
Copy Markdown
Contributor

Idel (@Idelmaeaen): You asked for a new pull request from this branch for the new M99 feature. Don't do that. Please create a new branch for each new feature or bug fix. Mixing several issues in one branch creates confusion and overhead.

So, if you want the new M99 command merged into master, then create a new branch for this feature. Also explain why you think this new feature is useful to other people, right now it is not clear to me as to why I would use it. Can you give an example of when people would use it?

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.