Context
Source: session recap email (2026-02-19)
Problem
Current simulation predicts lower losses than bench measurements. Candidate causes were identified (Rac, capacitor ESR, component models), but no structured investigation exists yet.
Expected Outcome
A calibrated model investigation closes the gap between simulation and measurement, starting with DC total loss alignment before AC refinements.
Scope
In:
- Quantify current simulation-vs-measurement mismatch.
- Test candidate contributors: Rac, capacitor ESR, component model updates.
- Prioritize matching
Ptot DC before extending to dynamic conditions.
Out:
- Major control software refactor.
- Bench hardware redesign.
Acceptance Criteria
Evidence / Notes
- Email excerpt: "Les premiers ajustements ont montré des pertes plus faibles entre simu et manipe ... Ajouts Rac, ESR condensateurs, modèles composants ... se rapprocher au niveau Ptot DC"
- Related files/paths:
simulations/Hackathon_Si_Losses.asc, simulations/Hackathon_Si_Losses_full.asc
- Related issue(s): none
Context
Source: session recap email (2026-02-19)
Problem
Current simulation predicts lower losses than bench measurements. Candidate causes were identified (Rac, capacitor ESR, component models), but no structured investigation exists yet.
Expected Outcome
A calibrated model investigation closes the gap between simulation and measurement, starting with DC total loss alignment before AC refinements.
Scope
In:
Ptot DCbefore extending to dynamic conditions.Out:
Acceptance Criteria
Evidence / Notes
simulations/Hackathon_Si_Losses.asc,simulations/Hackathon_Si_Losses_full.asc