Skip to content

onnxruntime range check for relu output #590

@wangtiance

Description

@wangtiance

For relu op, setting QuantizationProperty as SYMMETRICAL and quant_min/quant_max to 0/255 and export the graph with platform=TargetPlatform.ONNXRUNTIME causes warning messages like this:

[Warning] Is it not safe to export TQC(/cnn/cnn.0/cnn.0.2/Relu_output_0) to Onnx, INT8 value range must be [-128, 127] or [0, 255], however [(0, 255)] was given.

But setting quant_min/quant_max to -128 and 127 leads to slightly worse quantization errors. Should relu output be set as ASYMMETRICAL? or should i just ignore these warning messages?

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type
    No fields configured for issues without a type.

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions